Loading... Please wait...| SolarEdge 43.2kW String Inverter - SE43.2K-USRP0BNU4 |
|
SolarEdge, 43.2 KW, 3-Phase Grid Tied Inverter, (-40°C to 60°C) 208V - with AC RSD, DC Safety Switch and AFCI. Primary Unit - requires separate purchase of 2 Secondary units (SE-SU-USRS0NNN4), SE43.2K-USRP0BNU4 The SolarEdge PV inverter combines sophisticated digital control technology with efficient power conversion architecture to achieve superior solar power harvesting and best-in-class reliability. |
|
Features
|
| General Information | |
| Manufacturer: | SolarEdge |
| Product Line: |
North America Three Phase |
| Model ID: |
SE43.2K-USRP0BNU4c |
| Certifications and Safety Ratings: |
| Mechanical Data |
|
| Technology: | Three Phase String Inverter w/ Synergy Technology |
| Dimensions: |
37 x 12.5 x 10.5 inches |
| Weight: | 105.8 lbs |
| Cooling: | Fans (User Replaceable) |
| Number of Units: | 3 |
| Mount: | Bracket Mounted (Brackets Provided) |
| Electrical Data |
|
| Output | |
| Rated AC Power Output: | 43200 VA |
| Maximum AC Power Output: | 43200 VA |
| AC Output Line Connections: |
4-Wire WYE (L1-L2-L3-N) Plus PE or 3 Wire Delta |
| AC Output Voltage (L-N): | Minimum: 105VAC; Nominal: 120VAC; and Maximum: 132.5VAC |
| AC Output Voltage (L-L): | Minimum: 183VAC; Nominal: 208VAC; and Maximum: 5229VAC |
| AC Frequency: | Minimum: 59.3Hz; Nominal: 60Hz; and Maximum: 60.5Hz |
| Maximum Continuous Output Current: | 120 Amps per Phase |
| GFDI Threshold: | 1 |
| Utility Monitoring, Islanding Protection, County Configurable Power Factor, Country Configurable Thresholds: | Yes |
| Input | |
| Maximum DC Power (Module STC): | 58200 / 19400 Watts |
| Transformer-Less Ungrounded: | Yes |
| Maximum Input Voltage DC to Gnd: | 300 VDC |
| Maximum Input Voltage DC+ to DC-: | 600 VDC |
| Nominal Input Voltage DC to Gnd: | 200 VDC |
| Nominal Input Voltage DC+ to DC-: | 400 VDC |
| Maximum Input Current: | 114 ADC |
| Maximum Input Current: | 135 ADC |
| Reverse-Polarity Protection: | Yes |
| Ground-Fault Isolation Detection: | 350kΩ Sensitivity per Unit |
| CEC Weighted Efficiency: | 97% |
| Night-Time Power Consumption: | < 12 Watts |
| DC Safety Switch | |
| DC Disconnect: | 1000V / 3 x 40A |
| DC Surge Protection: | Optional, Type II, Field Replaceable |
| DC Fuses on Plus & Minus: | Optinal, 30A |
| Datasheets |
|
| Document | Type |
| Specifications | |
| Warranty | 12 Year Limited Product Warranty |
| Warranty |
| Terms & Conditions |
|
| Shipping: | Shipping Policy |
| Returns: | Returns Policy |
| Payments: | We accept: Visa, MasterCard, Discover, and American Express. We also accept checks, direct deposit and wire transfers for large orders. |
Warranty: 12 Year Limited Product Warranty