Enphase Energy, 230W 240-208VAC MC4 Type Micoinverter, S230-60-LL-2-US Built on the fifth-generation platform, the Enphase S230 Microinverter achieves the highest inverter efficiency for module-level power electronics. With its all-AC approach, the S230 simplifies design and installation for 230 VA installations, and delivers optimal energy harvest. The S230 is compatible with storage systems, including battery management systems. The Enphase S230 integrates seamlessly with the Enphase Envoy-S communications gateway, and Enphase Enlighten monitoring and analysis software. |
Features
|
General Information | |
Manufacturer: | Enphase Energy |
Product Line: |
S230 |
Model ID: |
S230-60-LL-2-US |
Certifications and Safety Ratings: | ![]() ![]() ![]() ![]() |
Mechanical Data |
|
Technology: | Micro-Inverter |
Dimensions: |
6.77 x 6.89 x 1.38 Inches |
Weight: | 4.00 lbs |
Compatibility: | 60-Cell PV Modules |
Communication: | Power-Line |
Integrated Ground: | The DC Circuit Meets the Requirements for Ungrounded PV Arrays in NEC 690.35. Equipment Ground is Provided in the Engage Cable. No Additional GEC or Ground is Required. Ground Fault Protection (GFP) is Integrated into the Microinverter. |
Monitoring: | Enlighten Manager and MyEnlighten Monitoring Options |
Compliance: | UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01 |
Enclosure Environmental Rating: | Outdoor - NEMA 6 |
Cooling: | Natural Convection - No Fans |
Connector Type: | S230-60-LN-2-US: MC4; S230-60-LN-5-US: Amphenol H4 |
CEC Weighted Efficiency: | 96.5% @208 VAC; 97.0% @240 VAC |
Peak Inverter Efficiency: | 96.7% @208 VAC; 97.2% @240 VAC |
Ambient Temperature Range: | -40°C to +65°C |
Electrical Data |
|
Commonly Used Module Pairings: | 195W-285W |
Maximum Input DC Voltage: | 48 Volts |
Peak Power Tracking Voltage: | 27-37 Volts |
Operating Range: | 16-48 Volts |
Min/Max Start Voltage: | 22 V / 48 Volts |
Max DC Short Circuit Current: | 15 A |
Peak Output Power: | 230VA @208VAC; 230VA @240VAC |
Maximum Continuous Output Power: | 220VA @208VAC; 220VA @240VAC |
Nominal Voltage/Range: | 208V / 183-229V @208VAC; 240V/211-264V @240VAC |
Nominal Output Current: | 1.06 A @208VAC; 0.92 A @240VAC |
Nominal Frequency/Range: | 60/57-61 Hz @208VAC; 60/57-61 Hz @240VAC |
Extended Frequency Range: | 57-63 Hz @208VAC; 57-63 Hz @240VAC |
Power Factor at Rated Power: | 1.0 @208VAC; 1.0 @240VAC |
Maximum Units per 20A Branch Circuit: | 25 (Three Phase) @208VAC; 17 (Single Phase) @240VAC |
Maximum Output Fault Current: | 663 mA rms, 100 ms @208VAC; 663 mA rms, 100 ms @240VAC |
Power Factor (Adjustable): | 1/0.7 Leading, 0.7 Lagging @208VAC; 1/0.7 Leading, 0.7 Lagging @240VAC |
Datasheets |
|
Document | Type |
![]() |
Specifications |
![]() |
Installation Guide |
Warranty | 15 Year Limited Warranty |
![]() |
Warranty |